Modbus & Modbus TCP Protocol Solutions
PROFIBUS DP Master/Slave to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial Gateway
PROFIBUS DP Slave to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial Gateway
4 Channel HART Input Module
4 Channel HART Output Module
PLX82-MBTCP-PNC Modbus TCP/IP to PROFINET Controller Gateway
PROFINET® Device to Modbus® Serial Gateway with four serial ports
PROFINET Device to Modbus Serial Gateway
Modbus® TCP/IP to PROFINET® Device Gateway - PLX31-MBTCP-PND
Modbus® TCP/IP to PROFINET® Device Gateway - PLX32-MBTCP-PND
Universal QuickServer Gateway
Puerta de Enlace de EtherNet/IP a Modbus TCP/IP a Servidor OPC UA
Registrador de Datos
Data Logger Plus
Modbus TCP/IP to IEC 60870-5-104 Gateway
Módulo para rede Modbus Maestro/Esclavo mejorado para ControlLogix
Modbus Serial Module for CompactLogix L1 and Point I/O Adapters ILX34-MBS232
Módulo de Comunicación Modbus TCP/IP Cliente/Servidor mejorado para ControlLogix®
Modbus Master/Slave Enhanced Network Interface Module with Reduced Data Block for ControlLogix
Modbus TCP/IP Client/Server Enhanced Network Interface Module with Reduced Data Block for ControlLogix
Modbus TCP/IP Multi Client Enhanced Network Interface Module with Reduced Data Block for ControlLogix
Modbus Serial Enhanced Communication Module
Modbus Serial Lite Communication Module for CompactLogix
Modbus TCP/IP Enhanced Communication Module
Modbus TCP/IP Lite Communication Module for CompactLogix
Modbus TCP/IP to Siemens Industrial Ethernet Gateway
Modbus TCP/IP to Modbus Master/Slave Gateway - 4 Port
Modbus TCP/IP to Modbus Serial Communication Module
EtherNet/IP to Modbus TCP/IP
EtherNet/IP to Modbus Serial
EtherNet/IP to Modbus Serial 4 Port
Modbus Serial Module for CompactLogix L1 and Point I/O Adapters ILX34-MBS485
Distributed Network Protocol (DNP3) Gateway
PA Link Series B
XPosition
Time Sync Module
CANopen Router
Modbus TCP/IP to IEC 61850 Dual Port Gateway
-
PLX51-PBM
-
PLX51-PBS
-
PLX51-HART-4I
-
PLX51-HART-4O
-
PLX82-MBTCP-PNC
-
PLX31-PND-MBS4
-
PLX31-PND-MBS
-
PLX31-MBTCP-PND
-
PLX32-MBTCP-PND
-
PS-QS-2x10-F
-
PLX32-EIP-MBTCP-UA
-
PLX51-DL-232
-
PLX51-DLplus-232
-
PLX32-MBTCP-104
-
MVI56E-MCM/MCMXT
-
ILX34-MBS232
-
MVI56E-MNET/MNETXT
-
MVI56E-MCMR
-
MVI56E-MNETR
-
MVI56E-MNETCR
-
MVI69E-MBS
-
MVI69L-MBS
-
MVI69E-MBTCP
-
MVI69L-MBTCP
-
PLX31-MBTCP-SIE
-
PLX31-MBTCP-MBS4
-
PLX31-MBTCP-MBS
-
PLX31-EIP-MBTCP
-
PLX31-EIP-MBS
-
PLX31-EIP-MBS4
-
ILX34-MBS485
-
PLX51-DNPS
-
A-PAL/B
-
A-XGPS
-
A-TSM/B
-
A-CANOR
-
PLX82-MNET-61850
PLX51-PBM
The PLX51-PBM gateway provides connectivity to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial networks for PROFIBUS DP networks by operating as either a Master or Slave device on the PROFIBUS DP network.
For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing the overall programming time for EtherNet/IP applications.
For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as PROFIBUS device discovery and a built-in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections to the processor, this module provides performance and data throughput back to the processor for even the most demanding of PROFIBUS applications.
When used as a PROFIBUS DP slave, the module can operate as 1 to 10 slaves, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP, Modbus TCP/IP, or Modbus Serial devices and a PROFIBUS DP master.
PLX51-PBS
The PLX51-PBS gateway provides connectivity to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial networks for PROFIBUS DP networks by operating as a PROFIBUS DP slave.
For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing programming time.
For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as a built in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections back to the processor, this module provides performance and data throughput for even the most demanding of PROFIBUS applications.
As a PROFIBUS DP slave device, the module can emulate from 1 to as many as 10 slave DP nodes, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP devices and a PROFIBUS DP master. This eliminates the need for using DPV1 messaging when more than 244 bytes of data needs to be exchanged between a PROFIBUS master and an EtherNet/IP network.
A conformal coating option is available for this product.
PLX51-HART-4I
The PLX51-HART-4I allows users to easily connect their existing HART-compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3 Ethernet networks. The module can be used to connect HART Input devices such as process instruments into an Ethernet network.
The PLX51-HART-4I supports up to 4 channels of HART communication, as well as Analog 4-20 mA signals for real-time process variables to/from the HART-compatible device.
PLX51-HART-4O
The PLX51-HART-4O allows users to easily connect their existing HART-compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3 Ethernet networks.
The module can be used to connect HART Output devices such as valve positioners into an Ethernet network. The PLX51-HART-4O supports up to 4 channels of HART communication, as well as Analog 4-20 mA signals for real-time process variables to/from the HART-compatible device.
PLX82-MBTCP-PNC
The Modbus® TCP/IP to PROFINET Controller Gateway allows you to connect two giants of industrial automation through secure, high-speed communications. The gateway provides Modbus TCP/IP-based controllers the ability to control up to 36 PROFINET RT devices such as field I/O, drives, HMIs, and controllers.
The PLX82-MBTCP-PNC gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
PLX31-PND-MBS4
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. Each Modbus serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS4 gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
PLX31-PND-MBS
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. The serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
PLX31-MBTCP-PND
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
PLX32-MBTCP-PND
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
PS-QS-2x10-F
The QuickServer line of communication gateways are designed to link building automation driven networks with industrial control networks. The QuickServer gateways are available with limits of up to 250, 500, or 1000 points of application data and connect building automation networks such as BACnet™ MS/TP, BACnet/IP, or JCI Metasys™ N2 with industrial control networks such as EtherNet/IP™, Modbus® RTU, or Modbus TCP/IP.
PLX32-EIP-MBTCP-UA
¿Necesita obtener la información de sus dispositivos basados en EtherNet/IP™ o Modbus® TCP/IP a sus clientes OPC UA para que sea analizada y usted pueda reducir sus costos de operación o incrementar su producción?
La puerta de enlace de comunicaciones de ProSoft Technology de EtherNet/IP a Modbus TCP/IP a OPC UA Server permite transferencias de datos tri-direccionales de alta velocidad entre PACs EtherNet/IP y dispositivos Modbus TCP/IP, al tiempo que proporciona una conexión de Servidor OPC UA.
El controlador Modbus TCP/IP cuenta con conexiones múltiples y simultáneas de clientes y servidores para una transmisión de datos más rápida. Se ofrece un EDS AOP para una integración simplificada y un tiempo de puesta en marcha reducido para los PACs de Rockwell Automation equipados con EtherNet/IP ®.
El Servidor OPC UA es altamente confiable y seguro y admite 10 sesiones OPC UA simultáneas que proporcionan acceso a datos EtherNet/IP y Modbus TCP/IP de sus redes respectivas.
PLX51-DL-232
¿Qué pasaría si pudiera almacenar los datos de sus dispositivos de control para mantenimiento preventivo o para mejorar sus procesos?
El Registrador de Datos PLX51-DL-232 es ideal para sitios remotos con comunicaciones limitadas donde se necesita registrar información. Los OEM pueden registrar la información de sus máquinas para identificar mejoras en la eficiencia o problemas de operación. El PLX51-DL-232 puede leer y almacenar datos de PLCs EtherNet/IP, PLCs y dispositivos serie DF1 o PLCs y dispositivos Modbus®. El PLX51-DL-232 tiene la capacidad de almacenar más de 16 millones de registros en su memoria no volátil de estado sólido. Cada registro almacenado incluye una Marca de Fecha y Hora, Nombre de Etiqueta, Tipo de Dato y Valor.
PLX51-DLplus-232
The PLX51-DLplus-232 Data Logger is ideal for remote sites with limited communications that need to log data. OEMs can log their machine’s data to identify operational problems or efficiency improvements and can view this data online as trends via an integrated webserver. The trend data can be exported as a CSV file. The module supports REST API to collect JSON encoded data from the module that can be sent to other systems.
The PLX51-DLplus-232 can read and store data from EtherNet/IP™ PLCs, DF1 Serial PLCs and devices, or Modbus® PLCs and devices. The PLX51-DLplus-232 has the capacity to store over 16 million records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp, Tag Name, Data Type, and Value.
Learn more about ProSoft’s Remote Connectivity Solutions.
PLX32-MBTCP-104
IIntegration of Modbus TCP/IP® products into IEC 60870-5-104 networks can be a challenge, but not with ProSoft Technology’s PLX32-MBTCP-104 gateway.
The gateway has dual Ethernet ports, providing the option to have one Ethernet port communicating on both Modbus TCP/IP and IEC 60870-5-104 networks, or independent communication ports for each protocol.
The gateway provides powerful communications on the Modbus TCP/IP network, operating as either a Client or a Server to various devices such as PLC’s, Drives, HMI’s and various other equipment supporting the Modbus TCP/IP protocol.
On the IEC 60870-5-104 side of the communications, the gateway operates as a server, accepting commands from client devices such as a SCADA system or DCS system.
MVI56E-MCM/MCMXT
Los módulos de comunicación Modbus Maestro/Esclavo MVI56E mejorados permiten a los procesadores ControlLogix® de Rockwell Automation® conectarse a los dispositivos usando el protocolo de comunicación en serie Modbus Serial RTU/ASCII.
Los MVI56E-MCM y MVI56E-MCMXT actúan como módulos de entrada/salida en el backplane del ControlLogix, haciendo que los datos de Modbus aparezcan como entrada/salida en el procesador. La transferencia de datos desde y hacia el procesador es asincrónica desde las comunicaciones en la red Modbus. Dos puertos seriales configurables de manera independiente pueden operar en la misma red Modbus o en diferentes redes. Cada puerto puede configurarse como Maestro o Esclavo Modbus, compartiendo la misma base de datos de 5000 palabras controlada por el usuario.
Los dos módulos son lo mismo desde el punto de vista funcional. El MVI56E-MCM está diseñado para aplicaciones de procesos estándar. El MVI56E-MCMXT está diseñado para la plataforma de control Logix-XT™, permitiéndole operar en entornos extremos. Puede tolerar temperaturas de operación más altas, y también cuenta con un revestimiento industrial para protegerlo de condiciones hostiles o caústicas.
ILX34-MBS232
ProSoft Technology’s ILX34-MBS232 module is ideal for point to point applications with a maximum distance of 50 feet away (15.2 meters) your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point I/O systems. In addition, the module can be configured as a Master or Slave.
MVI56E-MNET/MNETXT
El Módulo de Comunicación MVI56E Modbus TCP/IP Cliente/Servidor mejorado permite a los procesadores ControlLogix de Rockwell Automation® establecer fácilmente una interacción entre los PACs (Programable Automation Controlers) de Rockwell Automation y una amplia variedad de instrumentos y dispositivos compatibles con el protocolo Modbus TCP/IP.
Los módulos MVI56E mejorado incluyen configuración local y remota y diagnósticos a través del puerto Ethernet del módulo, así como tecnología CIPconnect® para realizar el ruteo de mensajes entre las redes ControlNet y EtherNet/IP de Rockwell Automation.
El MVI56E-MNET y MVI56E-MNETXT son iguales en cuanto a su función. El MVI56E-MNET está diseñado para aplicaciones de procesos estándar, mientras que el MVI56E-MNETXT está diseñado para la plataforma de control Logix-XT™, permitiéndole operar en entornos extremos. Puede tolerar temperaturas de operación más altas, del orden de los 70C, y también cuenta con un revestimiento industrial para protegerlo de condiciones hostiles y ambientes químicos y corrosivos.
MVI56E-MCMR
The MVI56E-MCMR Enhanced Modbus Master/Slave Communication Module with Reduced Data Block allows Rockwell Automation® ControlLogix® processors to easily interface with devices using the Modbus RTU/ASCII serial communications protocol. Compatible devices include a wide variety of instruments, process measurement devices, popular brands of programmable logic controllers (PLCs) and programmable automation controllers (PACs).
The MVI56E-MCMR acts as an input/output module on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Backplane data transfers to and from the processor are asynchronous from communications on the Modbus network. Two independently-configurable serial ports can operate on the same or different Modbus networks. Each port can be configured as a Modbus Master or Slave, sharing the same user-controlled 5000-word database.
The MVI56E-MCMR utilizes a reduced Input/Output (I/O) data block for transferring data to and from a ControlLogix processor. This reduced data block makes it ideal for use in remote rack applications over ControlNet™. For EtherNet/IP™ applications where bandwidth is not an issue, it is strongly recommended to use the MVI56E- MCM.
MVI56E-MNETR
Which of our Modbus TCP/IP modules is best for your application?
The Modbus TCP/IP Client/Server Enhanced Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices.
The MVI56E-MNETR uses a reduced Input/Output (I/O) data image block size for transferring data between itself and a ControlLogix processor. This makes it ideal for remote rack applications using ControlNet or EtherNet/IP process networks. The module also works well for applications that require redundant ControlLogix processors.
MVI56E-MNETR enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files.
MVI56E-MNETCR
Which of our Modbus TCP/IP modules is best for your application?
The MVI56E Modbus TCP/IP Multi Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP/IP server-compatible instruments and devices. The Multi Client module improves performance when controlling multiple servers on a Modbus TCP/IP network, by supporting up to 30 clients.
MVI56E enhancements include configuration and management through the module Ethernet port, CIPconnect technology for bridging through ControlNet and EtherNet/IP networks, and has a web server to access on-board documentation, Add-On Instructions, and sample program files.
This module uses a small I/O data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.
MVI69E-MBS
The MVI69E-MBS Modbus Serial module for CompactLogix™ is designed for all applications requiring Modbus Serial connectivity. This module comes with an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69E-MBS has two serial ports and can support both Master and/or Slave connectivity to interface with a variety of devices using the Modbus Protocol.
A conformal coating option is available for this product.
MVI69L-MBS
The MVI69L-MBS, Modbus Serial module for the CompactLogix™ series of controllers is designed for smaller applications where communication between a few Modbus Serial devices is required. This module has an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69L-MBS has a single serial port and can support either Master or Slave connectivity to interface with a variety of devices using the Modbus Protocol.
A conformal coating option is available for this product.
MVI69E-MBTCP
The MVI69E-MBTCP Modbus TCP/IP module for the CompactLogix™ series of controllers is designed for all applications requiring Modbus TCP connectivity. This module comes with an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69E-MBTCP has a single Ethernet port for diagnostic and application data. The module supports both Client and Server connectivity to interface with a variety of devices using the Modbus Protocol.
MVI69L-MBTCP
The MVI69L-MBTCP Modbus TCP/IP module is ideal for smaller applications that utilize the CompactLogix L2 controllers. The module has an Add-on Profile and an Add-on Instruction to reduce commissioning time.
The MVI69L-MBTCP has a single Ethernet port for diagnostic and application data. It supports both Client and Server connectivity to interface with a variety of devices using the Modbus TCP/IP Protocol.
A conformal coating option is available for this product.
PLX31-MBTCP-SIE
ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP controllers and Siemens® S7-400, S7-300, S7-200, S7-1200, and S7-1500 PACs.
In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
PLX31-MBTCP-MBS4
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.
In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
PLX31-MBTCP-MBS
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
PLX31-EIP-MBTCP
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ enabled controllers or devices and Modbus® TCP/IP controllers or devices.
Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
PLX31-EIP-MBS
ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices.
EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
The gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance
PLX31-EIP-MBS4
The EtherNet/IP® to Modbus Serial gateway offers bi-directional data transfers between Modbus Serial and the EtherNet/IP network. Our EtherNet/IP Driver uses Class 1 I/O connections and/or Class 3 Message instructions. Protocol conversion gateways are the ideal solution for distributed networks when adding a remote rack becomes too costly.
The PLX31-EIP-MBS4 gateways are stand-alone DIN-rail mounted gateways that provide one Ethernet port for communication, allowing for remote configuration and diagnostics, and up to four (4) serial communication ports. The PLX30 gateways also come with an SD Card slot (SD card optional) for storing configuration files. In the event of a failure the SD card can be transferred to another gateway reducing downtime. These gateways also come with a wide input power range (10 Vdc – 36 Vdc), and an extended temperature range (-25°C to 70°C ). The PLX30 gateways include all the necessary cables required for communication.
A conformal coating option is available for this product.
ILX34-MBS485
ProSoft Technology’s ILX34-MBS485 module is ideal to connect multiple devices up to 4,000 feet (1,219 meters) from your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point I/O systems. In addition, the module can be configured as a Master or Slave.
PLX51-DNPS
The PLX51-DNPS gateways provide intelligent routing between DNP3 (Distributed Network Protocol) and either EtherNet/IP™ or Modbus® protocols. The gateways support Ethernet and Serial communications.
PLX51-DNPS gateway is the DNP3 Outstation or Slave.
The PLX51-DNPS allows the user to integrate DNP3 devices over a secure link into a Logix system with minimal effort. No copying or mapping of data in the Logix controller is required as the PLX51-DNPS writes directly into Logix tags.
The PLX51-DNPS allows users to integrate the gateway into a Modbus TCP/IP or serial network. The gateway supports Modbus TCP/IP Client and Server and Modbus RTU protocols.
The PLX51-DNPS module provides DNP3 Secure Authentication 5 which enables the user to connect DNP3 devices to a Logix platform securely. The module also provides a range of diagnostics, statistics and a DNP3 traffic analyzer to assist with fault-finding.
A-PAL/B
The PROFIBUS PA gateway allows the user to interface PROFIBUS PA DPV0/DPV1 to either EtherNet/IP™ or Modbus® devices.
When configured as a Master, the PA Link can exchange up to 2 kilobytes of PROFIBUS PA device and status data.
The PA Link has two Ethernet ports for a Linear or Ring (Device Level Ring – DLR) Ethernet topology. The Ethernet ports can also be configured for port mirroring, allowing for better fault analysis.
The PA Link can synchronize to an NTP Server allowing for automatic time synchronization. It also supports an onboard non-volatile event log for improved fault finding. The PA Link has a built-in Power Conditioner which can supply up to 420 mA. The power conditioner is protected against a configurable overcurrent limit. The module also has a configurable built-in Fieldbus terminator.
The PA Link provides a range of statistics and tools to provide a detailed diagnostic overview of each PA Link, which speeds-up fault finding. The Slate Configuration Utility allows the user to perform a PROFIBUS PA packet capture of the running Fieldbus which can be used to analyze the bus behavior and packets received. The PA Link also provides global and device specific statistics.
A-XGPS
The XPosition module provides connectivity between high precision GPS and inertial navigation devices to Rockwell Automation’s Logix (ControlLogix® and CompactLogix™) family of controllers.
The module operates in a Logix “owned” mode. With a Logix connection the input and output assemblies will provide additional diagnostics information which will be available in the Logix controller environment.
The module uses an external GPS receiver to provide accurate position information. The external GPS or inertial navigation device provides various accuracy estimates allowing the user to make informed decisions for high precision position and velocity applications.
The XPosition module supports dual antenna receivers, allowing users to access Yaw, Tilt and Heading data.
The integrated webserver provides detailed diagnostics of system configuration and operation, including the display of GPS time, position, and velocity without the need for any additional software.
Check out a successful application with this solution: OEM Adds a Position Check to Mining Machine
A-TSM/B
The Time Sync module provides Precision Time Protocol (PTP - Grand Master) and NTP Time services. This enables precision time synchronization for Logix Controllers and HMI systems. It can also provide GPS position and velocity data. The module uses an on-board GPS receiver to provide accurate time and position information.
Because the module is stand-alone and connects to various devices over an Ethernet network the module can be placed as close as possible to the antenna position removing the need for costly low-loss coaxial cables that was traditionally needed to connect the GPS antenna to the module. The on-board GPS receiver also provides velocity and odometer reading allowing the user to implement the module in various vehicle and tracking applications. The GPS accuracy information provided allows the user/controller to make calculated decision when looking at the position, velocity, or odometer information.
A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of GPS time, position, and velocity without the need for any additional software.
A-CANOR
The CANopen® Router provides intelligent data routing between either EtherNet/IP™ or Modbus TCP/IP® and the CANopen bus network. This allows the user to integrate CANopen devices into a Rockwell® Logix platform (e.g. ControlLogix® or CompactLogix™) or any Modbus Master device with minimal effort.
The module can be configured to be either a Master or Slave allowing the user to not only integrate CANopen devices into a Logix or Modbus system, but to also allow the user to use Logix or Modbus devices in an existing CANopen network (by using the CANopen Router in Slave mode). In a Logix system the module uses Direct-To-Tag technology allowing CANopen devices to exchange data with a Logix controller without the need to write any ladder or application code in Studio 5000.
The module also provides a range of statistics to simplify the diagnostic process as well as a CANopen packet capture for remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CANopen operation and communication statistics, without the need for any additional software.
PLX82-MNET-61850
The Modbus TCP/IP to IEC 61850 gateway enables communication between the Intelligent Electronic Devices (IEDs) on an IEC 61850 network and Programmable Logic Controllers (PLCs) or Programmable Automation Controllers (PACs) on a Modbus TCP/IP network.
The configuration utility software provided with the gateway uses IED configuration files to import complex IEC 61850 data structures. The utility creates Variable files and Function Block files for import into Unity Pro projects for Quantum or M340 processors.
IEC 61850 is the international standard that defines the hardware and communication requirements for all devices within substation automation. The standardized naming conventions imposed by the IEC 61850 standard improves interoperability between systems provided by diverse manufactures or created by multiple system integrators.
Click Here for Additional Modbus Gateway Products
“Understanding Modbus Serial and TCP IP” is a quick tutorial for Rockwell Automation users on the Modbus protocol. The video is a great tool for anyone who is unfamiliar with how Modbus Serial and TCP IP operate, including information about function codes and data structures.