DNRB_Render

DeviceNet Router/B

A-DNTR/B

The DeviceNet Router/B provides a powerful and easy to configure solution to exchange data between DeviceNet™ and EtherNet/IP™, Modbus TCP/IP or Modbus RTU networks.

The module can be configured as a DeviceNet Scanner or a DeviceNet Device - allowing the user to not only integrate DeviceNet devices into a Logix or Modbus system, it also allows EtherNet/IP or Modbus devices in an existing DeviceNet network.

The DeviceNet Router B is configured using the Slate Configuration Utility software tool. 

The DeviceNet Router B includes a web server to display DeviceNet operation and communication statistics and advanced diagnostics functions like built-in packet capture for the various protocols. The router has two Ethernet ports to support Device-Level-Ring (DLR) architectures

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.

Características y Beneficios

  • DeviceNet Scanner or DeviceNet Device
  • Support for multiple DeviceNet network baud rates (125K, 250K, 500K)
  • Support for DeviceNet pass-through or explicit messaging
  • PCCC client mode to connect to Ethernet-only PanelViews to an existing DeviceNet network
  • EtherNet/IP Target or Originator with support for Class 1 connections
  • Supports Modbus TCP/IP (Ethernet) and Modbus RTU (Serial) Client/Server
  • Direct-to-Tag Technology
  • Dual Ethernet ports with support for DLR (Device Level Ring)
  • Support for NTP (Network Time Protocol) for external clock synchronization
  • Advanced Diagnostics, including packet capture

Configuración

The Slate Configuration Utility software is used for the configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the DeviceNet Router module, connections with controllers and devices.

Especificaciones

DeviceNet Network 

Specification

Description

Connector

5-way terminal, 5.08 mm pitch.

Modes

Scanner, Target (or Device)

Baud Rate

125k, 250k, 500k

DeviceNet Terminator

120 Ω (Software enabled)

DeviceNet Scanner

Specification

Description

Device Count

63

Set Target Device Node

Supported

Set Target Device Baud Rate

Supported

Device Discovery

Supported

Explicit Messaging

Supported

Supported Connections

Poll, Change of State (COS)

DeviceNet Target

Specification

Description

Supported Connections

Poll, Change of State (COS)

Input / Output Data Max

256 bytes input or output, per message

PCCC Network

Specification

Description

Max PCCC Connections

10

Max PCCC Payload

1000 bytes

EtherNet/IP Network

Specification

Description

Connector

RJ45

Conductors

CAT5 STP/UTP

ARP Connections

Max 100

TCP Connections

Max 100

CIP Connections

Max 15

Communication Rate

10/100 Mbps

Duplex Mode

Full / Half

Auto-MDIX Support

Yes

Embedded switch

Yes, 2 x Ethernet ports

Device Level Ring (DLR)

Yes

Network Time Protocol (NTP)

Yes

 

EtherNet/IP Originator

Specification

Description

Class 1 Cyclic Connections Supported

Yes

Class 3 / UCMM Connections Supported

Yes

Class 1 connection count

10

Class 3 / UCMM Target Device Count

10

Class 3 / UCMM Mapping Count

50

 

EtherNet/IP Target

Specification

Description

Class 1 Cyclic connection count

4

Logix Direct-To-Tag supported

Yes

 

Modbus Client

Specification

Description

Modes

Modbus TCP/IP, Modbus RTU (RS232 and 485)

Modbus RS485 Termination

125 Ω (Software enabled)

Maximum Modbus Server Devices

20

Maximum Modbus Registers mapped

100

Modbus address Range supported

0 to 65535 of each type (Holding/Input Register, Input/Coil Status)

Base Offset

Modbus (Base 0) ; PLC (Base 1)

Configurable Modbus TCP port

Yes

Data Reformatting Supported

BB AA

BB AA DD CC

CC DD AA BB

DD CC BB AA

 Modbus Server

Specification

Description

Modes

Modbus TCP/IP, Modbus RTU (232 and 485)

Modbus RS485 Termination

Software set

Modbus address Range supported

0 to 65535 of each type (Holding/Input Register, Input/Coil Status)

Base Offset

Modbus (Base 0) ; PLC (Base 1)

Configurable Modbus TCP/IP port

Yes

Serial Port (RS232)

Specification

Description

RS232 Connector

9-way terminal (shared with RS485)

RS232 Conductor

24 – 18 AWG

Electrical Isolation

1000 VDC

Baud Rates

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Parity/Data Bits/Stop Bits

None, Even, Odd / 8 / 1

 Serial Port (RS485)

Specification

Description

RS232 Connector

9-way terminal (shared with RS485)

RS232 Conductor

24 – 18 AWG

Electrical Isolation

1500 Vrms (1 minute, maximum)

Baud Rates

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Parity/Data Bits/Stop Bits

None, Even, Odd / 8 / 1

Hardware

Specification

Description

Power Supply

Input: 10 to 32 VDC, (85 mA @ 24 VDC and 180mA @ 10 VDC)

Power Consumption

2.2 W

Dimensions

149.0 x 34.0 x 116.0 mm (H x W x D)

Connector

3-way terminal

Conductors

24 to 18 AWG

Enclosure Rating

IP20, NEMA/UL Open Type

Temperature

-20 to 70 °C

Humidity

0 to 95% RH, non-condensing

Earth Connection

Yes, terminal based

Emissions

IEC61000-6-4

ESD Immunity

EN 61000-4-2

Radiated RF Immunity

IEC 61000-4-3

EFT/B Immunity

IEC 61000-4-4

Surge Immunity

IEC 61000-4-5

Conducted RF Immunity

IEC 61000-4-6

Certificaciones

UL/cUL; Class1, Div 2 238,99 kB Última Modificación 25.01.2024
CE Declaration of Conformity (CE, UKCA, RoHS, UL) 339,65 kB Última Modificación 26.01.2024
ATEX Letter Of Conformity 101,09 kB Última Modificación 13.10.2023