5127-Serial-HART

Modbus Master/Slave to HART Multi-drop 8 channel

5127-MCM-HART

Descontinuado: Producto no disponible en stock. More Info

The ProLinx Modbus Master/Slave to HART Multi-Drop Gateway creates a powerful connection between devices on a Modbus network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight configurable HART channels.

The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

Applications

The MCM-HART modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate HART serial devices into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART device support, the module provides a very powerful interface to the over two-million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Aplicaciones

The MCM-HART modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate HART serial devices into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART device support, the module provides a very powerful interface to the over two-million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Especificaciones

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (without condensation)

Dimensions

Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)

Extended:
 5.20 in H x 2.73 in W x 4.52 in D (13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
HART Channel Activity (Green)

(Ethernet-equiped Gateways Only)
Ethernet Link
Ethernet Activity

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

RJ45 Connector

Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

HART Interface

Four (4) HART Multi-drop channels

Screw terminals for each channel

24 VDC power supply
(third-party, not supplied with the gateway)

Must have sufficient current capacity to supply all loop-powered HART devices

Screw terminals for 24 VDC available on HART connector, supplied with the gateway, for loop-powered configurations

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5 mm screwdriver
CD (docs and Configuration utility)
RS232-to-RS422/RS485 Screw Terminal Adapter(s) (Serial Gateways Only)
HART Terminal Block connector

Descargas

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114,23 kB Última Modificación 13.11.2023
MCM HART Datasheet 70,71 kB Última Modificación 26.04.2010
MCM Driver Manual 835,78 kB Última Modificación 10.12.2009
HART Driver Manual 922,47 kB Última Modificación 15.09.2017

Protocolos

HART Protocol Specification


The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.


Protocol Specifications

The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters

Communication parameters

Number of HART Preambles: 2 to 50

Enable Handheld: Y or N

Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable, Short / Long Address Retries, Retries After Error

Poll Time After Error, Number of Commands, Slave List Error Pointer

HART Driver

Command List

Up to 100 fully configurable commands per channel

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

HART® is a registered trademark of the HART Communication Foundation


MCM Protocol Specification


The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.


Protocol Specifications

The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

General Parameters - Modbus Protocol

Communication parameters

Baud Rate: 110 to 115K baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds

Error Checking

RTU mode (binary) with CRC-16
ASCII mode with LRC error checking

Floating Point

Floating point data movement supported, including configurable support for Enron implementation

Function Codes

1: Read Output Status
2: Read Input Status
3: Read Multiple Data Registers
4: Read Input Registers
5: Write Single Bit
6: Write Single Data Register
15: Write Multiple Bits
16: Write Multiple Data Register

Modbus Master

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

Polling of command list

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Node address

1 to 247 (software selectable)


Certificaciones

CB Safety 35,78 kB Última Modificación 27.04.2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Última Modificación 10.07.2020
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Última Modificación 10.07.2020
UL/cUL; Class 1, Div 2 1,08 MB Última Modificación 31.03.2020
UL Certificate of Compliance - Canada 1,10 MB Última Modificación 16.11.2022