ProSoft Technology has a number of educational and tutorial videos to help our customers in the setup and configuration of our products. These are all available free of charge on our website and on YouTube, so that you can watch them at your convenience. We are always making more tutorial videos so if you do not see the one you are looking for, give us a call.
Troubleshooting Tips for New or Established Wireless Networks
Troubleshooting Tips for New or Established Wireless Networks Wireless radios can boost reliability in your operation, but sometimes problems can arise. This educational video will focus on common causes behind radio communication issues, and explain what you should check if you’re having a problem with a new or existing wireless communication network. To learn more about industrial wireless solutions and what you should consider for your application, go to http://psft.com/C1M.
|
10 Things to Consider When Deploying Industrial Wireless Communications Industrial wireless communications can bring several benefits to your facility – but planning before deployment is a must. In this educational video, you’ll find out the factors you need to consider, from the best radio frequency and channel for your application to the devices involved. Learn more about your industrial wireless communications options at http://psft.com/CU3.
|
Designing and Installing an RS485 Serial Network Due to the wide range of an RS485 serial network, it has become the basis of frequently used industrial automation protocols such as Modbus® RTU, DH-485, and Optomux. This educational video gives you tips on designing, installing, and troubleshooting an RS485 serial network so you can get your operation up and running quickly.
|
Understanding Modbus Serial and TCP/IP This tutorial teaches you about Modbus Serial and Modbus TCP/IP communications as well as Modbus addressing, data structures, function codes and physical network considerations. RS232, RS485, RS422 and Ethernet topologies are discussed.
|
Understanding Client, Server & I/O Messaging for Ethernet Networks ProSoft’s Industrial Ethernet video will help you understand how to select the best method for your application no matter which protocol you choose.
|
A Guide to Wi-Fi and Frequency Hopping Antenna Selection If you need to know what antenna to use for your 802.11abgn or Frequency Hopping wireless application, this is the video to watch. ProSoft’s “Guide to Antenna Selection” video will answer your questions on what type of antenna to use, where to mount it and why. This is the wireless 101 video you have been looking for.
|
Setup Tutorial: Siemens S7-200, S7-300, S7-400, S7-1200, S7-1500 to ControlLogix via Ethernet This tutorial will take you through the steps of configuring the MVI56E-SIE module and setting up a project in RSLogix 5000 that will allow a ControlLogix processor to read and write data to Siemens S7 CPU's.
|
Setup Tutorial: Modbus TCP/IP Multi Client/Server Enhanced Network Interface Module for ControlLogix This tutorial will help you setup an MVI56E-MNETC as a client and a server on a ModBus TCP I/P Network. This video will teach you how to import and modify the Add-On-Instructions, setup and configure in PCB and create client commands.
|
Setup Tutorial for DNP3 over Ethernet ControlLogix® module as a Server This video teaches you how to communicate to DNP3 over Ethernet devices with a ControlLogix® system using ProSoft Technology's MVI56E-DNPNET module. You will learn how to create a project in RSLogix™ 5000 or Studio 5000™, import an Add-On Instruction, configure the module as a server and access the modules diagnostics using ProSoft Configuration Builder
|
Setup Tutorial for DNP3 over Ethernet ControlLogix® module as a Client This video teaches you how to communicate to DNP3 devices with a ControlLogix® system using ProSoft Technology's MVI56E-DNPNET module. You will learn how to create a project in RSLogix™ 5000 or Studio 5000™, import an Add-On Instruction, configure the module as a client, create client commands and access the modules diagnostics using ProSoft Configuration Builder.
|
Setup Tutorial for the PROFIBUS DP-V1 Master Communication Module for ControlLogix - MVI56-PDPMV1 Learn how to set up the MVI56-PDPMV1 PROFIBUS module in your ControlLogix processor. This video covers setup in RSLogix 5000 as well as Ladder Logix.
|
MVI56E-MNET Modbus TCP/IP Communications Interface Module The ProSoft Technology MVI56E Modbus TCP/IP Communication Module is designed to allow ControlLogix processors to interface easily with other Modbus TCP/IP protocol-compatible devices.
|
Setup Tutorial for ControlLogix Modbus Master/Slave Module using the MVI56E-MCM module This training video takes you step-by-step through actual screen shots for the setup and configuration of the MVI56E-MCM module as a Modbus Master communicating with a slave device. You will be using an Add-On Instruction and an Add-On Profile to simplify your configuration.
|
Modbus Master/Slave Tutorial for Diagnostics on MVI56E-MCM, MVI56E-MCMXT The MVI56E Modbus Master/Slave Enhanced Communication Modules (MVI56E-MCM, MVI56E-MCMXT) allow Rockwell Automation ControlLogix processors to easily interface with devices using the Modbus RTU/ASCII serial communication protocol.
|
Setting up your ProSoft Flow Computer for ControlLogix This video takes you step by step through the configuration of ProSoft Technology’s Enhanced Flow Computer for ControlLogix® systems. The single flow computer setup can help you simplify your operation, reduce your capital spend and maintenance costs, and optimize your oil production.
|
|
Set Up: Setting up your ProSoft Flow Computer for CompactLogix™ Flow Computer for CompactLogix™ systems. The MVI69E-AFC can help you simplify your operation, reduce your capital spend and maintenance costs, and optimize your oil production.
|
|
Modbus Serial Setup Tutorial for CompactLogix MVI69E-MBS Learn how to set up the MVI69E-MCM module using RSLogix and Add-On Instructions.
|
Modbus TCP/IP Setup Tutorial for CompactLogix MVI69E & L-MBTCP This tutorial will show you how to set up an MVI69E-MBTCP to read and write to a Quantum PLC. This will include things such as adding the module profile to RSLogix 5000, Adding the MVI69E-MBTCP to the 1769 backplane, creating commands to exchange data to a Quantum PLC, Installing an Add-On-Instruction and some trouble shooting techniques.
|
Setup Tutorial for a PROFIBUS Master for CompactLogix Using the ILX69-PBM This training video takes you step-by-step through actual screen shots for the setup and configuration of the ILX69-PBM PROFIBUS Master. Installing an Add-On Instruction, an Add-On Profile, using the FDT Configuration software, installing GSD files allowing you to send and receive PROFIBUS data between Rockwell’s CompactLogix and Profibus Slaves.
|
Setup Tutorial for a PROFIBUS Slave for CompactLogix Using the ILX69-PBS This training video takes you step-by-step through actual screen shots for the setup and configuration of the ILX69-PBS PROFIBUS slave allowing you to send and receive PROFIBUS data between Rockwell’s CompactLogix and a Profibus master.
|
MVI69-DNP 3.0 Master/Slave Communications Module The MVI69 DNP 3.0 module is a single slot, backplane compatible DNP 3.0 interface solution for the Rockwell Automation CompactLogix platform. This module provides highly configurable support of both DNP 3.0 Master and Slave implementations (level 2 minimum), allowing the many SCADA and field devices supporting the DNP protocol to be integrated into the powerful CompactLogix platform.
|
PROFIBUS DP Master Configuration Software - PS69-DPM PROSOFT.fdt is an FDT (Field Device Tool) compatible frame application that allows you to easily create, configure and monitor PROFIBUS networks using the PS69-DPM Master and any compatible PROFIBUS DP Slave device.
|
Set Up: DH+ to EtherNet/IP PanelView migration gateway for PLC5sThis training video takes you step-by-step through actual screen shots for the setup and configuration of the A-B Remote I/O DH+ Gateway using the DHP firmware; allowing you to upgrade an existing DH+ PanelView to a newer EtherNet/IP PanelView Plus 6 for PLC5.
|
Set Up: Connect your HART field devices to EtherNet/IP , Modbus® TCP/IP, and DNP3 Ethernet networksProSoft Technology’s PLX51-HART 4I and 4O gateways enable users to easily connect their existing HART-compatible field devices to Ethernet networks. In this video, we’ll show you how to set up the HART-4I to extract data from a level sensor on a HART network and map it to a Logix controller over EtherNet/IP. This video will also cover the HART-4O configuration.
|
Set Up: Enable a SCADA on OPC UA to get Data from an EtherNet/IP or Modbus TCP Device
Set Up: Enable a SCADA on OPC UA to get Data from an EtherNet/IP or Modbus TCP DeviceProSoft Technology’s PLX32-EIP-MBTCP-UA gateway brings together EtherNet/IP™, Modbus® TCP/IP, and OPC UA to help you get the information you need to make data-driven decisions that will benefit your operation. In this step-by-step video, you’ll learn how to set up the gateway to enable a SCADA on OPC UA to get data from a device on an EtherNet/IP or Modbus TCP network.
|
Set Up: Upload and Download PLC programs from an EtherNet/IP™ PC to a DF1 PLC
Set Up: Upload and Download PLC programs from an EtherNet/IP™ PC to a DF1 PLCSince Rockwell Automation® discontinued the 1761-NET-ENI, you may be wondering how you can connect your EtherNet/IP™ and DF1 equipment. Some good news: ProSoft Technology’s PLX51-DF1-ENI Routing Module can be used in place of the 1761-NET-ENI. In this video, you’ll learn how the module’s Bridge Mode can be used to upload and download your PLC program from an EtherNet/IP PC to a DF1 PLC.
|
Set Up: Sending data between a DF1 slave device and an EtherNet/IP™ Logix controller
Set Up: Sending data between a DF1 slave device and an EtherNet/IP™ Logix controllerTrying to modernize your DF1-based operation to one utilizing EtherNet/IP™? ProSoft Technology’s PLX51-DF1-MSG Messaging Module allows for a lower-risk, phased modernization of your DF1 equipment. In this video, you’ll learn how to set up the module’s Scheduled mode, setting up communications between a DF1 slave device and an EtherNet/IP Logix-based controller.
|
Set Up: DF1 master device polling an EtherNet/IP™ Logix controller
Set Up: DF1 master device polling an EtherNet/IP™ Logix controllerTrying to modernize your DF1-based operation to one utilizing EtherNet/IP™? ProSoft Technology’s PLX51-DF1-MSG Messaging Module allows for a lower-risk, phased modernization of your DF1 equipment. In this video, you’ll learn how to set up the module’s DF1 Server, or slave, mode so you can connect a DF1 master device and an EtherNet/IP™ Logix-based controller.
|
|
Set Up: Connect Your Wired Gateway to Remote Equipment
Set Up: Connect Your Wired Gateway to Remote EquipmentThis video takes you step by step through the configuration of ProSoft’s wired remote access solution, the Network Bridge, including how to create a Belden Horizon account. Learn more about ProSoft’s Secure Remote Access solutions at http://psft.com/CIY.
|
Set Up: Allowing a Modicon® to control a PROFINET device
Set Up: Allowing a Modicon® to control a PROFINET deviceThe Modbus® TCP/IP to PROFINET Gateway allows Modbus TCP/IP-based processors to control up to 36 PROFINET RT devices. In this video, we’ll take you step by step in setting up the gateway to enable a Modicon® controller to read and write a 32-bit floating point value to a PROFINET drive.
|
Set Up: Allowing your ControlLogix® to control a PROFINET device
Set Up: Allowing your ControlLogix® to control a PROFINET deviceThe EtherNet/IP™ to PROFINET Gateway allows EtherNet/IP-based processors from Rockwell Automation® to control up to 36 PROFINET RT devices. In this video, we’ll take you step by step in setting up the gateway to enable a ControlLogix® to read and write a 32-bit floating point value to a PROFINET device.
|
Set Up: For AB Remote I/O™ to EtherNet/IP™ drive migration gateway
Set Up: For AB Remote I/O™ to EtherNet/IP™ drive migration gatewayThis video teaches you how to setup ProSoft's AN-X2-AB-DHRIO gateway with the AB-DRV-04 firmware to migrate up to four legacy Remote I/O drives to PowerFlex™ drives without modifying PLC code. You will learn how to use the gateway's onboard web interface to configure IP settings as well as create and download .csv files with the RIO drive configuration settings and data mapping for the Ethernet drive.
|
Setup Tutorial for AB Remote I/O™ to EtherNet/IP™ PanelView migration gateway for PLC5sThis video teaches you how to setup ProSoft's AN-X2-AB-DHRIO gateway to migrate legacy Panelviews™ to PanelView Plus 6 terminals without modifying PLC code. You will learn how to use the gateway's onboard web interface to configure IP settings, download and create a .csv file to configure the Remote I/O settings and use FactoryTalk View Studio to configure the PanelView Plus 6.
|
Firmware Selection Guide for AN-X2-AB-DHRIO Gateway
Firmware Selection Guide for AN-X2-AB-DHRIO GatewayProSoft’s AN-X2-AB-DHRIO gateway can be used to initiate a phased migration approach when replacing or upgrading legacy Allen-Bradley® equipment. At the beginning of that process, you select the correct firmware for your application. This supplement to our training video offers explanations of each of the types of firmware so you can select the appropriate one.
|
Setup Tutorial for the Modbus TCP to Siemens Industrial Ethernet GatewayThis short training video takes you step-by-step through actual screen shots for the setup and configuration of the Modbus TCP to Siemens Industrial Ethernet Gateway.
|
Setup Tutorial for the Modbus TCP to Modbus Serial Gateway This 5 minute training video takes you step-by-step through actual screen shots for the setup and configuration of the Modbus TCP to Modbus Gateway.
|
Setup Tutorial for the EtherNet/IP to Siemens Industrial Ethernet GatewayThis short training video takes you step-by-step through actual screen shots for the setup and configuration of the EtherNet/IP to Siemens Industrial Ethernet Gateway.
|
Setup Tutorial for the EtherNet/IP to Modbus TCP Gateway
Setup Tutorial for the EtherNet/IP to Modbus TCP GatewayThis 5 minute training video takes you step-by-step through actual screen shots for the setup and configuration of the EtherNet/IP to Modbus TCP Gateway.
|
Setup Tutorial for the EtherNet/IP to Modbus Serial Gateway This short training video takes you step-by-step through actual screen shots for the setup and configuration of the EtherNet/IP to Siemens Industrial Ethernet Gateway.
|
Quick Configuration of ProSoft's ASCII to EtherNet/IP Gateway TutorialThis video will show you, in just 6 minutes, how easy is it to configure ProSoft's ASCII to EtherNet/IP Gateway.
|
EtherNet/IP and OPC Connection to PLX30 GatewaysLearn how to configure Rockwell Automation's RSLinx software to easily pass data via an OPC connection to ProSoft Technology's PLX30 Gateways.
|
Setup for transferring data between a PROFINET controller and a Modbus TCP device PLX32-MBTCP-PNDThis training video takes you step-by-step through actual screen shots for the setup and configuration of the PLX32-MBTCP-PND. We’ll set-up and configure the gateway to allow an S7 PROFINET Controller to read and write a 32 bit floating point value to a device on a Modbus TCP/IP network.
|
Setup Tutorial for EtherNet/IP to PROFINET IO Device PLX32-EIP-PND GatewayThis video teaches you how to set up our EtherNet/IP™ to PROFINET IO Device Gateway to connect EtherNet/IP-based Rockwell Automation® controllers to PROFINET-based Siemens® controllers. You will learn how to assign the gateway an IP address on different subnets; configure the gateway using ProSoft Configuration Builder; connect a PROFINET controller to the gateway using Siemens Step 7™ configuration software and how to add the gateway as an I/O connection in Logix Designer, RS Logix 5000 or Studio 5000.
|
Setup for transferring data between a PROFINET controller and a Modbus Serial device PLX31-PND-MBS4This training video takes you step-by-step through actual screen shots for the setup and configuration of the PLX31-PND-MBS4. We’ll set-up and configure the gateway to allow an S7 PROFINET Controller to read and write a 32 bit floating point value to a slave device on a Modbus Serial network.
|
Setup Tutorial for EtherNet/IP to PROFINET IO Device GatewayThis video teaches you how to set up our EtherNet/IP to PROFINET IO Device Gateway to connect EtherNet/IP-based Rockwell Automation controllers to PROFINET-based Siemens controllers. You will learn how to assign the gateway an IP address; configure the gateway using ProSoft Configuration Builder; connect a PROFINET controller to the gateway using Siemens configuration software and how to add the gateway as an I/O connection in RS Logix 5000 or Studio 5000.
|
Setup Tutorial for the EtherNet/IP to BacNet IP GatewayThis training video takes you step-by-step through actual screen shots for the setup and configuration of the EtherNet/IP to BacNet IP Gateway allowing you to send and receive analog and digital data between BacNet IP compatible devices and a Rockwell PLC.
|
PROFIBUS DP Slave (PDPS) driverThe ProLinx family EtherNet/IP to PROFIBUS DP Slave communications module (5205-DFNT-PDPS) creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS master device. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port.
|
Modbus TCP/IP to PROFIBUS DPV1 Master Gateway
The ProLinx Modbus TCP/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB-9F port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi- Master network. The module supports the DPV1 specification.
|
Multi-Point Wireless I/O System: Inputs to OutputsOur Multi-Point Wireless I/O system lets you connect I/O to I/O, Modbus® serial to I/O, or Modbus serial to Modbus serial. This training video shows you how to configure the system to connect two remote I/O devices to a control center, step by step. The systems deploy quickly, and let users avoid pulling wires, conduit, trenching, and permits.
|
Multi-Point Wireless I/O System: Modbus to I/OOur Multi-Point Wireless I/O system lets you connect I/O to I/O, Modbus® serial to I/O, or Modbus serial to Modbus serial. This training video shows you how to configure the system to connect a Remote I/O device and a Modbus device to a control center, step by step. The systems can be deployed quickly, and let users avoid pulling wires, conduit, trenching, and permits.
|
Setup Tutorial for the Wireless I/O SystemThis training video takes you step-by-step through actual screen shots and live action shots for the setup and configuration of the complete Wireless I/O system. Explanation and wiring of the radio module, digital modules, 4-20 mA analog modules, 0-10 V analog modules, best RF practices, and going over the advanced user interface software. Wireless I/O Radio Kit BM-xx00-RM1K, Wireless I/O Analog 0-10 V Module BM-A010-122x, Wireless I/O Analog 4-20 mA Module BM-A420-122x, Wireless I/O Digital/Discrete Module BM-D100-144x
|
|
Guide to 32-bit data types in ProSoft Modbus modules
Tech Support: Guide to 32-bit data types in ProSoft Modbus modules Wondering how to handle 32-bit data types in your ProSoft Technology Modbus® communication module? In this supplement to our training videos, you’ll find out! Since the modules' internal memory consists of 16-bit words, you have to break the 32-bit register into two separate registers. This video takes you through that process!
|
Guide to bit-level data addressing in ProSoft Modbus modules
Guide to bit-level data addressing in ProSoft Modbus modules Wondering how to handle binary data in your ProSoft Technology Modbus® communication module? This video explores how bit-level information is stored in the modules' internal database. Find out how bit-level addressing differs from regular word addressing, and how you can convert one to the other.
|
Data Organization in ProSoft Modules and Gateways
Data Organization in ProSoft Modules and Gateways Wondering how data is organized in ProSoft Technology modules and gateways? This video explores how information is stored in the modules' internal database. Find out the difference between the ReadData and WriteData sections, and how you can control them.
|
Set Up: Troubleshooting Modbus error codes
Set Up: Troubleshooting Modbus® error codes You may have seen Modbus® error codes before, but do you know what they mean? In this supplement to our tutorial videos, we’ll explore some common Modbus error codes, and let you know what you should check for when you see them. This video can help you get back up and running faster. The codes this video covers include Standard Modbus Protocol Errors, Module Communication Error Codes, Command List Entry Errors, and Client Specific Errors.
|
Identify Modbus Com Errors
Identify Modbus Com Errors If something is wrong in your application because of a communication problem, you would like to know where to start looking to fix the issue. In this video, you’ll learn how to configure our Modbus® modules to quickly alert you to any Modbus communication errors. This feature will help you reduce your troubleshooting time.
|
ProSoft’s Data Analyzer: View Actual Data While Troubleshooting
ProSoft's Data Analyzer: View Actual Data While Troubleshooting When you're troubleshooting solutions in your operation, you usually just see how the device interprets issues - so sometimes you miss the full picture of what is going on with your network. With the Data Analyzer mode in ProSoft Configuration Builder software - and armed with a little knowledge of Modbus messages - you can more accurately handle issues on your network on a deeper level. This video will cover setting up the Data Analyzer mode; the composition of Modbus messages; and how to save your communication log in this helpful tool.
|