PROFIBUS DPV1 PS69 Slave Network Interface Module for CompactLogix

PS69-DPS

Disponibilidad Limitada: Producto en stock limitado. More Info
Recommended replacements: ILX69-PBS

The PS69-DPS module expands the functionality of Rockwell Automation’s CompactLogix™ to include PROFIBUS DP V0/V1. The PS69-DPS is a more cost-effective option offering more features than the MVI69-PDPS, and supports both I/O control and messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and acyclic messaging.

The PS69-DPS interface appears to the CompactLogix controller as a standard I/O module allowing it to be configured via RSLogix™ 5000, or configuration can be transferred from the Master to the PS69-DPS. For third party configuration a GSD file is supplied. The slave interface provides a diagnostic interface and has rotary switches for setting of the bus address. Complete program examples for simple and quick start-up are available.

Each module is equipped with LEDs to display communication and device status.

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

 

 Features

 Benefits

PROFIBUS Certified

Recognized quality certification mark

DPV1 supported

Provides for acyclic messaging, extended diagnostics and extended data support

Ladder logic module configuration

Better Rockwell Automation® integration using ladder logic software

Aplicaciones

Configuration

The GSD file supplied is sufficient to integrate the PS69-DPS as a PROFIBUS DP Slave into the configuration of any PROFIBUS Master. The PROFIBUS address is set by rotary switches. The slave configuration can be either transferred from the Master to the PS69-DPS or can be defined from the Logix application.

Especificaciones

  • Single Slot - 1769 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder logic is used for data transfer between module and processor. Sample ladder file included.
  • Supports CompactLogix processors and MicroLogix™ 1500 LRP

 

Specification

Description

Processor

EC1-160P with integrated ASPC2

PROFIBUS Interface

RS-485, max. 12 Mbps, potential free, according EN 50170

Diagnostic Interface

RS-232, PS/2 Mini-DIN female connector, 9600 Baud, non isolated

Power Supply

260 mA at +5 V ±5 %

Power Supply Distance Rating

6
(no more than 6 modules away from the 1769 power supply)

Dimensions

Standard 1769 Single-slot module

Burst

EN 61000-4-4, 2 kV, 5 kHz

Surge

EN 61000-4-5, 2 kV common mode, 1 kV differential mode

ESD

EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

Radiated/ Conducted Immunity

EN 61000-4-3, 10 V/m, 30 to 1000 MHz, 80% AM, 1 kHz sinewave

EN 61000-4-6, 10 V, 0.15 to 30 MHz

Radiated/ Conducted Emission

EN 55011 Class A

Vibration/Shock

IEC 600068-2-6, 10 to 150 Hz,
 ± 0.75 mm, ± 1 g, 1 Octave/min

IEC 600068-2-27, 15 g, 11 ms

Operating Temp.

32° F to 140° F (0° C to 60° C)

Relative Humidity

5% to 95% (without condensation)

Agency Certification

C-UL certified, UL 508 listed, CE

PROFIBUS conformance

PNO certified

 

Functional Specifications

Specification

Description

Master

According to IEC 61158

Slaves

max. 125 with the use of separate repeaters. 32 devices allowed per segment with up to 4 segments

Input Data

max. 408 Bytes (*)

Output data

max. 480 Bytes (*)

DPV0/V1 services

Fail Safe Mode, Global Control, Sync and Freeze, Watchdog, Read Request, Write Request, Alarm and Extended Diagnostics

Configuration Software

· FDT software creates Generic DTMs from the GSD file· Monitoring and Modification of process data· Online slave diagnostics

FDT/DTM Support

PROSOFT.fdt FDT software included along with a master and network configuration DTM. The DTM acts as a communication DTM for networked slave devices.

 (*) Can differ on different type of CompactLogix™ Controller and depends on total amount of I/O data of a CompactLogix System.The maximum length of a bus segment depends on the baud rate used. Only PROFIBUS certified cable, preferably the cable type A, should be used.

Certificaciones

ATEX Letter of Conformity 83,59 kB Última Modificación 12.05.2022
CB Safety 347,28 kB Última Modificación 26.02.2020
CE Mark 91,88 kB Última Modificación 22.02.2013
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Última Modificación 10.07.2020
UL/cUL; Class 1, Div 2 1,12 MB Última Modificación 27.02.2019
UL/cUL; Class 1, Div 2 (Canada) 1,14 MB Última Modificación 27.02.2019
Declaration of Conformity 440,44 kB Última Modificación 18.12.2020
Declaration of REACH Compliance 340,56 kB Última Modificación 08.02.2021