ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.

The gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

  • Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth. 
  • Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time. 
  • Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery. 
  • ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet. 
  • Secure module configuration via module switch (v1.04 and greater). 
  • Up to 10,000 16-bit registers can be used to exchange large amounts of data.

Especificaciones

EtherNet/IP™ Specifications 

Specification

Description

Number of Class 3 Server Connections

5

Supported PLC Types

PLC2, PLC5, SLC, CLX, CMPLX, MICROLX

Supported Message Types

PCCC and CIP

Class 3 Client Connections

Connected: 2
Unconnected: 1

Number of Class 1 I/O Connections

2

I/O connection sizes

248/248

Max RPI time

5 ms per connection

CIP Services Supported

0x4C - CIP Data Table Read
0x4D - CIP Data Table Write
CIP Generic

Command List

Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.

Command Sets

PLC-2/PLC-3/PLC5 Basic Command Set
PLC5 Binary Command Set
PLC5 ASCII Command Set
SLC500 Command Set

Modbus Serial Specifications 

Specification

Description

Command List

Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.

Supported Modbus Function Codes

1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)

Software configurable communication parameters

Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd Data Size: 7 or 8 bits Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds
Modbus RTU mode (binary) with CRC-16
Modbus ASCII mode with LRC error checking
Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations

Polling of Command List

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained

Node Address

1 to 247 (software selectable)

RS Interface

RS232, RS422, and RS485

Transmit and Receive Buffer Size

255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character

Hardware

Specification

Description

Power Supply

24 VDC nominal 10 to 36 VDC allowed Positive, Negative, GND Terminals

Current Load

24 VDC nominal @ 300 mA
10 to 36 VDC @ 610 mA maximum

Operating Temperature

-25°C to 70°C (-13°F to 158°F)

Storage Temperature

-40°C to 80°C (-40°F to 176°F)

Shock

IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)

Vibration

IEC 60068-2-6; 5G @ 10 to 150 Hz

Relative Humidity

5% to 95% RH with no condensation

Dimensions (H x W x D)

5.38 x 1.99 x 4.38 in
13.67 x 5.05 x 11.13 cm

LED Indicators

Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit Serial Communication Port Receive (RX) and Transmit (TX)

Ethernet Port

10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Number of Serial Ports

1

Serial Port Isolation

2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440,Si8441,Si8442)

Shipped With Each Unit

2.5 mm screwdriver
J180 Power Connector
(1) RJ45-DB9M Serial Adapter Cable (serial protocol)
(1) DB9 to Screw Terminal Adapter (serial protocol)

Certificaciones

ATEX Letter of Conformity 107,32 kB Última Modificación 12.05.2022
CB Safety 348,30 kB Última Modificación 20.10.2022
Korean KC Registration 974,32 kB Última Modificación 07.07.2020
UL Certificate of Compliance 233,35 kB Última Modificación 16.11.2022
Declaration of Conformity (RoHS/CE) 114,24 kB Última Modificación 01.06.2022
ODVA EtherNet/IP - Declaration of Conformity 183,48 kB Última Modificación 09.11.2020
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Última Modificación 10.07.2020
Declaration of REACH Compliance 145,49 kB Última Modificación 01.06.2022