The ProLinx DNP Slave to PROFIBUS DP Slave Gateway creates a powerful connection between DNP and PROFIBUS master devices. This stand-alone DINrail mounted protocol gateway provides one serial port and one PROFIBUS Slave port.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The DNPM-PDPS modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The DNP 3.0 Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The DNPS-PDPS modules are the ideal solution for the many applications where PROFIBUS connectivity can be used to integrate DNP serial devices into a system. The PROFIBUS gateway is a powerful module designed with Client support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
This area is used to store error codes, counters, and port status information for each port.
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Specification |
Description |
Power Supply |
24 VDC nominal |
Current Load |
500 mA max @ 32 VDC max |
Operating Temperature |
-4° F to 122° F (-20° C to 50° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Relative Humidity |
5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
LifeCycle Letter 5000 Selected Series | 114,23 kB | Última Modificación 13.11.2023 |
DNPS PDPS Datasheet | 98,76 kB | Última Modificación 26.04.2010 |
DNPS Driver Manual | 1,01 MB | Última Modificación 10.12.2009 |
PDPS Driver Manual | 684,88 kB | Última Modificación 10.12.2009 |
ProLinx GSD File | 398,03 kB | Última Modificación 11.05.2010 |
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters |
|
Internal Database |
Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer |
Communication parameters |
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 milliseconds |
DNP Mode |
DNP 3.0 Slave - Level 2 |
DNP Slave |
|
Node address |
0 to 65534 (software selectable) |
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters |
|
GSD File |
PRLX05A5.GSD Downloadable from ProSoft Technology web site |
PROFIBUS Specifications |
|
Communication parameters |
Baud Rate: 9.6 kbps to 12 Mbps |
Supported I/O length |
244 bytes Input data 244 bytes Output data 400 bytes total |
Supported PROFIBUS DP features |
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting |
Configurable Parameters |
PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database |
CB Safety | 35,78 kB | Última Modificación 27.04.2022 |
Korean KC Registration | 851,60 kB | Última Modificación 13.03.2020 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Última Modificación 10.07.2020 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Última Modificación 10.07.2020 |
UL/cUL; Class 1, Div 2 | 1,08 MB | Última Modificación 31.03.2020 |
UL Certificate of Compliance - Canada | 1,10 MB | Última Modificación 16.11.2022 |