Modbus® TCP/IP to Siemens® Industrial Ethernet Communication Gateway

PLX32-MBTCP-SIE

ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.

Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. 

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

  • Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device’s IP address to be on the same subnet.
  • In addition to S7 controllers, the gateway can also be used with Siemens S5 controllers with an appropriate interface.
  • Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.

Especificaciones

Specification

Description

Supported Modbus Function Codes 

1: Read Coil Status 
2: Read Input Status 
3: Read Holding Registers 
4: Read Input Registers 
5: Force (Write) Single Coil 
6: Preset (Write) Single Holding Register 
15: Force (Write) Multiple Coils 
16: Preset (Write) Multiple Holding Registers 
22: Mask Write Holding Register (Slave Only) 
23: Read/Write Holding Registers (Slave Only)

Supported Clients 

10

Supported Servers 

MBAP - 5
Encapsulated - 5 

Command List

Up to 160 fully configurable Client commands

Status Data

Error codes reported individually for each command 

Command List Polling

Each command can be individually enabled or disabled; 
write-only-on-data-change is available 

Protocolos

MBTCP Protocol Specifications


MBTCP Protocol Specifications


Protocol Specifications

Modbus TCP/IP

Modbus Commands Supported

(Client and Server)

1: Read Coil Status

2: Read Input Status

3: Read Holding Registers

4: Read Input Registers

5: Force (Write) Single Coil

6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils

16: Preset (Write) Multiple Holding Registers

Configurable Parameters

(Client and Server)

Gateway IP Address

Modbus data type starting address offsets

Floating-point start address and database offset

Configurable Parameters

(Client Only)

Minimum Command Delay

Response Timeout

Retry Count

Command Error Pointer

Command List

Up to 100 fully configurable Client commands

Status Data

Error codes reported individually for each command

Command List Polling

Each command can be individually enabled or disabled; write-only-on-data-change is available


SIE Protocol Specification


Protocol Specifications

Specification

Description

Supported PLC Data Exchange (Read and Write)

Siemens S7-200, Siemens S7-300, Siemens S7-400,
Siemens S7-1200

Supported Register Types

DB, Inputs, Outputs, Flags, Counters, Timers

Supported Clients

20


Certificaciones

Declaration of Conformity (RoHS/CE) 296,29 kB Última Modificación 25.09.2017