Modbus TCP/IP to Modbus Serial Communication Module

PLX31-MBTCP-MBS

ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.

In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

  • Supports up to 20 simultaneous client & server connections, allowing for faster communication between devices such as HMIs, SCADA systems, power monitors and flow computers, among others. 
  • Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery. 
  • ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet. 
  • Secure module configuration via module switch (v1.04 and greater). 
  • Up to 4000 16-bit registers can be used to exchange large amounts of data.

Especificaciones

Modbus® TCP/IP Specifications

Specification

Description

 

Supported Modbus Function Codes

1: Read Coil Status 2: Read Input Status

3: Read Holding Registers 4: Read Input Registers

5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils

16: Preset (Write) Multiple Holding Registers

22: Mask Write Holding Register (Slave Only)

23: Read/Write Holding Registers (Slave Only)

Supported Clients

10

 

Supported Servers

MBAP: 5

Encapsulated: 5

 

Command List

Up to 160 fully configurable Client commands

Status Data

Error codes reported individually for each command

Command List Polling

Each command can be individually enabled or disabled;

write-only-on-data-change is available

Modbus Serial Specifications

Specification

Description

 

Command List

Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.

Supported Modbus Function Codes

1: Read Coil Status 2: Read Input Status

3: Read Holding Registers 4: Read Input Registers

5: Force (Write) Single Coil 6: Preset (Write) Single

Holding Register

15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers

22: Mask Write Holding Register (Slave Only)

23: Read/Write Holding Registers (Slave Only)

Software configurable communication parameters

Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd

Data Size: 7 or 8 bits

Stop bits: 1 or 2

RTS on/off delay: 0 to 65535 milliseconds Modbus RTU mode (binary) with CRC-16 Modbus ASCII mode with LRC error checking

Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations

Polling of Command List

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained

Node Address

1 to 247 (software selectable)

RS Interface

RS232, RS422, and RS485

 

Transmit and Receive Buffer Size

255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character

Hardware

Specification

Description

Power Supply

24 VDC nominal

10 to 36 VDC allowed

Positive, Negative, GND Terminals

Current Load

24 VDC nominal @ 300 mA

10 to 36 VDC @ 610 mA maximum

Operating Temperature

-25°C to 70°C (-13°F to 158°F)

Storage Temperature

-40°C to 80°C (-40°F to 176°F)

Shock

IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)

IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)

Vibration

IEC 60068-2-6; 5G @ 10 to 150 Hz

Relative Humidity

5% to 95% RH with no condensation

Dimensions (H x W x D)

5.38 x 1.99 x 4.38 in

13.67 x 5.05 x 11.13 cm

LED Indicators

Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit

Serial Communication Port Receive (RX) and Transmit (TX)

Ethernet Port

10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as

specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Number of Serial Ports

1

Serial Port Isolation

2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440,Si8441,Si8442)

Shipped With Each Unit

2.5 mm screwdriver J180 Power Connector

(1) RJ45-DB9M Serial Adapter Cable (serial protocol)

(1) DB9 to Screw Terminal Adapter (serial protocol)

Protocolos

MBS Protocol Specifications


MBS Protocol Specifications


Protocol Specifications

Modbus Master

A port configured as a virtual Modbus Master actively issues Modbus commands to other nodes on the Modbus network. The Master ports have an optimized polling characteristic that polls slaves with communication problems less frequently.

Command List

Up to 100 commands per Master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

Polling of Command List

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained per active Modbus Master port.

Modbus Slave

A port configured as a Modbus slave permits a remote Master to interact with all data contained in the module. This data can be derived from other Modbus slave devices on the network, through a Master port, or from the module.

Node Address

1 to 247 (software selectable)

Status Data

Error codes, counters and port status available per configured slave port


PLX30-MBTCP Protocol Secifications


Protocol Specifications

EtherNet/IP® Specifications

 Number of Class 3 Server Connections

5

Supported PLC Types

PLC2, PLC5, SLC, ControlLogix

Supported Message Types

PCCC and CIP

Number of Class 3 Client Connections

Connected
Unconnected

2
1

Number of Class 1 I/O Connections

PLX-31-EIP-MBTCP

2

I/O connection sizes

248/248

Max RPI time

5ms per connection

CIP Services Supported

0x4C - CIP Data Table Read
0x4D - CIP Data Table Write

Command List

Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.

Command Sets

PLC-2/PLC-3/PLC5 Basic Command Set
PLC5 Binary Command Set
PLC5 ASCII Command Set
SLC500 Command Set

 

Modbus TCP/IP Specifications

Supported Modbus Function Codes

1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)

Supported Clients

10

Supported Servers

 

MBAP
Encapsulated

5
5

 

Command List

Up to 160 fully configurable Client commands

Status Data

Error codes reported individually for each command

Command List Polling

Each command can be individually enabled or disabled; write-only-on-data-change is available

 

Modbus Serial Specifications

Command List

Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.

Supported Modbus Function Codes

1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)

Software configurable communication parameters

Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd Data Size: 7 or 8 bits Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds
Modbus Modes RTU mode (binary) with CRC-16ASCII mode with LRC error checking, Floating point data movement supported including configurable support for Enron and Daniel implementations

Polling of Command List

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained per active Modbus Master port.

Node Address

1 to 247 (software selectable)

RS Interface

RS232, RS422, and RS485


Certificaciones

Ex Certificate (ATEX Directive) 84,06 kB Última Modificación 22.05.2015
CB Safety 327,80 kB Última Modificación 22.05.2015
Korean KC Registration 548,37 kB Última Modificación 22.05.2015
UL/cUL; Class 1, Div 2 67,02 kB Última Modificación 19.03.2013
Declaration of Conformity (RoHS/CE) 297,32 kB Última Modificación 25.07.2018