The ProLinx EtherNet/IP to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
The DFNT-PDPMV1 modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. EtherNet/IP (Explicit Messaging) Compatible Devices Rockwell Automation equipment that supports EPIC:
The DFNT-PDPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
This area is used to store error codes, counters, and port status information for each port.
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
DFNT PDPMV1 Datasheet | 169,11 kB | Última Modificación 02.05.2016 |
PROFIBUS comDTM Datasheet | 143,67 kB | Última Modificación 11.03.2010 |
PROFIBUS comDTM Software | 7,66 MB | Última Modificación 03.06.2013 |
DFNT Protocol Manual | 2,03 MB | Última Modificación 24.07.2013 |
PDPMV1 Protocol Manual | 3,04 MB | Última Modificación 08.02.2017 |
PROFIBUS comDTM Quick Start Guide | 695,02 kB | Última Modificación 12.05.2010 |
PLX EDS File | 333,95 kB | Última Modificación 10.05.2010 |
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information |
|
Messaging |
PCCC on CIP |
Miscellaneous |
125 word read and write data lengths |
EtherNet/IP Server Specifications
In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications |
|
Connections | Five independent TCP server sockets permit remote clients to interact with all data contained in the module. |
Data File |
Data Table File Start - Fixed at N10 |
CIP Services Supported |
0x4C - CIP Data Table Read |
EtherNet/IP Client Specifications
In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications |
|
General | One client |
Command List | Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. |
Polling of command list | User configurable polling of commands, including disabled, continuous and on change of data (write only). |
List of Rockwell Automation material that support EPIC:
The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.
PROFIBUS Master Specifications
PROFIBUS Master Port
The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
Ex Certificate (ATEX Directive) | 114,27 kB | Última Modificación 11.11.2013 |
CB Safety | 35,78 kB | Última Modificación 27.08.2012 |
Declaration of Conformity (RoHS/CE) | 300,09 kB | Última Modificación 04.03.2018 |
Russian GOST-R | 7,07 MB | Última Modificación 22.02.2013 |
GOST-R Declaration of Conformity | 6,68 MB | Última Modificación 22.02.2013 |
Korean KC Registration | 851,60 kB | Última Modificación 22.02.2013 |
UL/cUL; Class 1, Div 2 | 1,08 MB | Última Modificación 02.07.2013 |
UL/cUL; Class 1, Div 2 (Canada) | 1,10 MB | Última Modificación 02.07.2013 |