The ProLinx EtherNet/IP to GE Ethernet Global Data Gateway creates a powerful connection between EtherNet/IP and GE Ethernet Global Data networks. The module provides one Ethernet port.

The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.

The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.

Características y Beneficios

Applications

The DFNT-EGD modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). In combination with the GE Ethernet Global Data device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. EtherNet/IP (Explicit Messaging) Compatible Devices Rockwell Automation equipment that supports EPIC:

  •  PLC5/E rev C/N, D/E, E/D
  •  SLC5/05 series A, OS503 frn4
  •  1785-ENET Series A, rev D
  •  Interchange V6.2
  •  MicroLogix 1100/1400/ANY via 1761-NET-ENI or PLX51-DF1-ENI
  •  CompactLogix 1768-L43/L45 via 1768-ENBT
  •  CompactLogix 1769-L32E/L35E/ANY
  •  CompactLogix L23E
  •  RSLinx Gateway V1.7+
  •  ControlLogix 1756-ENET/ENBT/EN2T/EN2TR

Aplicaciones

The DFNT-EGD modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). In combination with the GE Ethernet Global Data device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Especificaciones

The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

Descargas

ProSoft Configuration Builder (PCB)
LifeCycle Letter 5000 Selected Series 114,23 kB Última Modificación 13.11.2023
DFNT EGD Datasheet 145,95 kB Última Modificación 29.04.2014
DFNT Protocol Manual 2,03 MB Última Modificación 24.07.2013
EGD Protocol Manual 901,86 kB Última Modificación 05.08.2016
PLX EDS File 52xx-53xx 333,95 kB Última Modificación 19.11.2020

Protocolos

DFNT Protocol Specification


The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.


Protocol Specifications

The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.

General Protocol Information

Messaging

PCCC on CIP
Explicit Messaging supported

Miscellaneous

125 word read and write data lengths
Floating point data supported

EtherNet/IP Server Specifications

In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.

EtherNet/IP Server Specifications

Connections

Five independent TCP server sockets permit remote clients to interact with all data contained in the module.

Data File

Data Table File Start - Fixed at N10
Data Table File Size - 100 or 1000 words

CIP Services Supported

0x4C - CIP Data Table Read
0x4D - CIP Data Table Write

EtherNet/IP Client Specifications

In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.

EtherNet/IP Client Specifications

General

One client

Command List

Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

Polling of command list

User configurable polling of commands, including disabled, continuous and on change of data (write only).

EtherNet/IP (Explicit Messaging) Compatible Devices

List of Rockwell Automation material that support EPIC:

  • PLC5/E rev C/N, D/E, E/D
  • SLC5/05 series A, OS503 frn4
  • 1785-ENET Series A, rev D
  • Interchange V6.2
  • MicroLogix 1100/1400/ANY via 1761-NET-ENI
  • CompactLogix 1768-L43/L45 via 1768-ENBT
  • CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
  • RSLinx Gateway V1.7+
  • ControlLogix 1756-ENET/ENBT/EN2T

EGD Protocol Specification


The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.


Protocol Specifications

GE Fanuc Automation and GE Drive Systems developed an Ethernet Global Data, or EGD, exchange for PLC and computer data in 1998. GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume.

The module supports the following functions specified in the EGD protocol:

Code

Description

3

Retrieve Configuration Request (example provided)

4

Retrieve Configuration Response (example provided)

7

Summary Request

8

Summary Response

9

Capabilities Request

10

Capabilities Request

15

Statistics Request

16

Statistics Response

18

Command NAK

32

Read Request

33

Read Response

34

Write Request

35

Write Response

36

Masked Write Request

37

Masked Write Response


Certificaciones

ATEX Letter of Conformity 114,27 kB Última Modificación 12.05.2022
CB Safety 35,78 kB Última Modificación 27.04.2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Última Modificación 10.07.2020
Korean KC Registration 807,00 kB Última Modificación 13.03.2020
UL/cUL; Class 1, Div 2 1,08 MB Última Modificación 31.03.2020
UL Certificate of Compliance - Canada 1,10 MB Última Modificación 16.11.2022