The PROFIBUS DP Slave module is a powerful communication interface for Unity and Quantum platform processors that allows you to interface easily with a PROFIBUS DP Master device. Developed under license from Schneider Electric, the module incorporates proprietary backplane technology that enables powerful data exchange with Unity and Quantum processors.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the module and Scneider Electric Quantum and Unity processors. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The PTQ module Configuration/Debug Serial port connects a PC to the module for configuration, status, monitoring, and troubleshooting (Serial cable is included with product shipment). After editing on a PC, a configuration file is downloaded and stored on the PTQ module.
The PROFIBUS DP Slave gives access to the unit's input and output images with up to 244 bytes of Input and Output data, for a maximum of 400 bytes total. These Input and Output data blocks are mapped by the user within the inRAx module's data memory allowing maximum flexibility and data transfer with other protocols.
With the growing usage of the PROFIBUS DP protocol in the industrial marketplace, this product has a wide variety of application uses. Industries that use this technology include:
Specification |
Value |
Backplane Current Load |
5 VDC ± 5% |
Operating Temperature |
32° F to 140° F (0° C to 60° C) |
Storage Temperature |
-40° F to 185° F (-40° C to 85° C) |
Relative Humidity |
5% to 95% (without condensation) |
Vibration |
Sine vibration 4 to 100 Hz in each of the 3 orthogonal axes |
Shock |
30 g, 11 ms in each of the 3 orthogonal axes |
Module LED Indicators |
Module Status |
PROFIBUS LED Indicators |
Network Activity |
Configuration Serial Port (PRT1) |
DB-9M PC Compatible |
Configuration Ethernet port |
RJ45 Connector Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
PROFIBUS Slave Port |
DB-9F Optically Isolated RS-485 |
PTQ LifeCycle Letter | 393,51 kB | Última Modificación 23.01.2020 |
ProSoft Configuration Builder (PCB) | ||
PTQ-PDPS Datasheet | 331,79 kB | Última Modificación 12.11.2018 |
PTQ PDPS App Ref Guide | 1,53 MB | Última Modificación 27.04.2010 |
PTQ-PDPS GSD File | 11,09 kB | Última Modificación 12.05.2010 |
PTQ-PDPS Configuration File | 1,30 kB | Última Modificación 15.12.2009 |
ATEX Letter of Conformity | 106,86 kB | Última Modificación 12.05.2022 |
CB Safety | 39,05 kB | Última Modificación 08.10.2012 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Última Modificación 10.07.2020 |
UL/cUL; Class 1, Div 2 | 1,18 MB | Última Modificación 08.04.2019 |
UL/cUL; Class 1, Div 2 (Canada) | 1,21 MB | Última Modificación 10.09.2014 |