$ EZ-EDS Version 3.3 (enhanced (beta), October-18, 2010) Generated Electronic Data Sheet $ DeviceNet Electronic Data Sheet $ Copyright (C) 2002 Rockwell Automation [File] DescText = "EDS File for the ProSoft ILX34-MBS 1734 Modbus Module"; CreateDate = 09-07-2012; CreateTime = 09:49:45; ModDate = 03-07-2014; ModTime = 07:20:59; Revision = 1.010; HomeURL = "http://www.ab.com/networks/eds/DN/0001007300850100.eds"; [Device] VendCode = 309; VendName = "ProSoft Technolgy"; ProdType = 12; ProdTypeStr = "Communications Adapter"; ProdCode = 4002; $ 0085 (hex) MajRev = 1; MinRev = 14; ProdName = "ILX34-MBS485"; Catalog = "ILX322-MBS485"; Icon = "0001_1734Purple.ico"; $ Speciality module, Key = 2 [IO_Info] Default = 0x0004; PollInfo = 0x0001, 1, 1; COSInfo = 0x0005, 1, 1; CyclicInfo = 0x0008, 1, 1; Input1 = 26, 0, 0x000D, "Consume 1", 6, "20 04 24 66 30 03", "8 Integers"; Input2 = 58, 0, 0x000D, "Consume 2", 6, "20 04 24 68 30 03", "24 Integers"; Input3 = 82, 0, 0x000D, "Consume 3", 6, "20 04 24 6A 30 03", "36 Integers"; Output1 = 30, 0, 0x000D, "Produce 1", 6, "20 04 24 65 30 03", "8 Integers"; Output2 = 62, 0, 0x000D, "Produce 2", 6, "20 04 24 69 30 03", "24 Integers"; Output3 = 86, 0, 0x000D, "Produce 3", 6, "20 04 24 6B 30 03", "36 Integers"; [ParamClass] Revision = 1; MaxInst = 16; Number_Of_Static_Instances = 16; Descriptor = 0x0009; CfgAssembly = 0; [Params] Param1 = 0, $ reserved, shall equal 0 6,"20 0F 24 01 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Framing", $ name "", $ units "Modbus Character Framing", $ help string 0,5,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1 = 0,"7N2", 1,"7E1", 2,"7O1", 3,"8N2", 4,"8E1", 5,"8O1"; Param2 = 0, $ reserved, shall equal 0 6,"20 0F 24 02 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Protocol", $ name "", $ units "0 = ASCII/1 = RTU", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum2 = 0,"ASCII", 1,"RTU"; Param3 = 0, $ reserved, shall equal 0 6,"20 0F 24 03 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Consume Assy", $ name "", $ units "Modbus Consume Assembly", $ help string 102,108,102, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum3 = 102,"Data Size 8 Ints", 106,"Data Size 24 Ints", 108,"Data Size 36 Ints"; Param4 = 0, $ reserved, shall equal 0 6,"20 0F 24 04 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Baudrate", $ name "", $ units "", $ help string 0,4,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum4 = 0,"19200", 1,"2400", 2,"4800", 3,"9600", 4,"38400"; Param5 = 0, $ reserved, shall equal 0 6,"20 0F 24 05 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Type", $ name "", $ units "Master/Slave", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum5 = 0,"Master", 1,"Slave"; Param6 = 0, $ reserved, shall equal 0 6,"20 0F 24 06 30 01", $ Link Path Size, Link Path 0x0102, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "Modbus Produce Assy", $ name "", $ units "Modbus Produce Assembly", $ help string 101,107,101, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum6 = 101,"Data Size 8 Ints", 105,"Data Size 24 Ints", 107,"Data Size 36 Ints"; Param7 = 0, $ reserved, shall equal 0 6,"20 0F 24 07 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "Modbus Timeout", $ name "", $ units "Timeout for receive of Modbus message", $ help string 0,65535,2000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param8 = 0, $ reserved, shall equal 0 6,"20 0F 24 08 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "Modbus SlaveID", $ name "", $ units "0 to 255", $ help string 0,127,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param9 = 0, $ reserved, shall equal 0 6,"20 0F 24 09 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "In Coil Start", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param10 = 0, $ reserved, shall equal 0 6,"20 0F 24 0A 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "In Coil Count", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param11 = 0, $ reserved, shall equal 0 6,"20 0F 24 0B 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "Out Coil Start", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param12 = 0, $ reserved, shall equal 0 6,"20 0F 24 0C 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "Out Coil Count", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param13 = 0, $ reserved, shall equal 0 6,"20 0F 24 0D 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "In Reg Start", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param14 = 0, $ reserved, shall equal 0 6,"20 0F 24 0E 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "In Reg Count", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param15 = 0, $ reserved, shall equal 0 6,"20 0F 24 0F 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "Out Reg Start", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param16 = 0, $ reserved, shall equal 0 6,"20 0F 24 10 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "Out Reg Count", $ name "", $ units "", $ help string -32768,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [Groups] Group1 = "Modbus Parameters", 8, 1,2,3,4,5,6,7,8; Group2 = "Coil Parameters", 4, 9,10,11,12; Group3 = "Register Parameters", 4, 13,14,15,16; [Assembly] Revision = 2;