Modbus TCP/IP to HART Analog Gateway (8 Chan)

5228-MNET-HART

The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a Modbus TCP/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.

Imágenes

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Características y Beneficios

Applications

The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Especificaciones

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply Input

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

1-4 ch: 190 mA max @ 32 VDC max
5-8 ch: 250 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (without condensation)

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D
 (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
 (13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
HART Channel Activity (Green)

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

HART Interface

Four (5x08) or eight (5x28) HART Point-to-Point Analog Input channels
Screw terminals for each channel

Electrical Isolation

1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

Common Mode Rejection

105db @ DC

Over current

± 40 mA continuous, maximum

Overvoltage Protection

All HART Inputs:
 90 V, 3-electrode gas discharge tube surge arrestor
 30 V MOV for voltage protection
 300 mA poly switch-resettable fuse for over current protection

Accuracy

0.05% of reading @ 25°C for signals between 4 mA to 20 mA

Built-in 24 VDC loop output power

1 Internal 24 VDC power supply for each 4 channels.
Screw terminals for Isolated 24 VDC loop power may be used to provide HART loop power.

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5 mm screwdriver
RS232-to-RS422/RS485 Screw Terminal Adapter(s) (Serial Gateways Only)
CD (docs and Configuration utility)
HART Terminal Block connector

Certifications

CE, cCSAus (Class I, Div 2, Groups ABCD), and ATEX (pending)

Descargas

ProSoft Configuration Builder (PCB)
MNET HART Analog Datasheet 181,58 kB Última Modificación 25.02.2015
MNET Protocol Manual 631,11 kB Última Modificación 16.02.2012
HART Analog Protocol Manual 663,68 kB Última Modificación 16.02.2012

Protocolos

HART Analog Protocol Specification


The HART Analog protocol driver works as a single current loop, point-to-point Master on four channels (all channels set up as channel 0). Each channel is individually configurable.


Protocol Specifications

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters

Communication parameters

Number of HART Preambles: 2 to 50
Enable Handheld: Y or N
Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable, Short / Long Address Retries, Retries After Error
Poll Time After Error, Number of Commands, Slave List Error Pointer

HART Driver

Command List

Up to 100 fully configurable commands per channel

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

Isolated HART Analog Input Specifications

Input Range

Current: 4 to 20mA with HART

Resolution

16bits

Input Filter

First Order Sync: 10 Hz

Current Input Resistance

247.6 ohms +/- 1%

Open circuit detection time

1/2 second maximum

Over current

+/-40mA continuous, maximum

Common Mode Noise Rejection

105dB

Calibrated Accuracy @ 25°C

4 to 20 mA: 0.05% of reading

Input Isolation Voltage

2500 V RMS per UL 1577, transformer isolated

24V DC Isolation Voltage

1500 VDC

HART® is a registered trademark of the HART Communication Foundation


MNET Protocol Specification


The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.


Protocol Specifications

The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.

Modbus TCP/IP Server

General

Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.

Configurable Parameters

Module IP Address
Modbus address offsetting

Modbus TCP/IP Client

General

Actively reads and writes data with Modbus TCP/IP compatible devices.

One client connection (up to 100 servers/devices with 100 commands)

Configurable parameters

Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer

Command List

Up to 100 fully configurable commands on the Client port


Certificaciones

Ex Certificate (ATEX Directive) 114,27 kB Última Modificación 11.11.2013
CB Safety 35,78 kB Última Modificación 27.08.2012
CE Mark 92,31 kB Última Modificación 22.02.2013
Russian GOST-R 7,07 MB Última Modificación 22.02.2013
GOST-R Declaration of Conformity 6,68 MB Última Modificación 22.02.2013
UL/cUL; Class 1, Div 2 1,08 MB Última Modificación 02.07.2013
UL/cUL; Class 1, Div 2 (Canada) 1,10 MB Última Modificación 02.07.2013