Modbus TCP/IP to CC-Link Local & Intelligent Station Gateway

5209-MNET-CCLINK

ProSoft Technology's Modbus TCP/IP to CC-Link communication gateway allows Schneider Electric control platform users to integrate CC-Link Master compatible products with existing Modbus TCP/IP control networks.

The Modbus TCP/IP driver supports Schneider Electric processors as well most other devices that use Modbus TCP/IP. The driver allows Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. An optional web interface can be ordered separately to add FTP (ftp://) support.

The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.

Características y Beneficios

Powerful network integration

  • Communicate between dissimilar networks
  • A shared 10.000-word database exchanges information from devices on both networks
  • Allows integration of Modbus TCP/IP-based systems into a CC-Link Master-controlled network

Modbus TCP/IP

  • Client and/or Server communication configurations supported
  • Five simultaneous Server connections on TCP/IP Service Port 502 and five additional Server connections on any unreserved service port (typically TCP/IP Service Port 2000)
  •  One Client connection supports up to 100 commands to interface with processors or other Server-based devices

CC-Link Intelligent or Local Station

  • Compatible with CC-Link Version 1.10
  • Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity
  • Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station
  • As a Local Station, provides a read-only list of all network slaves’ cyclic and status data
  • CC-Link Partner Association (CLPA) Certification

Backed by ProSoft Technology®

  • 20-year history of delivering high-quality, reliable solutions designed with you in mind
  • Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
  • Three-Year Warranty ensures reliability and protects against equipment failures
  • Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications

Configuración

ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.

Especificaciones

ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation.

 

Modbus TCP/IP

ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks.

Floating point data movement is supported, including configurable support for Enron or Daniel® floating point implementations.

 

Modbus Server (Slave)

The server driver accepts incoming connections on Service Port 502 for clients using the Modbus TCP/IP MBAP message format and from clients on Service Port 2000 (or other Service Ports) for clients using the Encapsulated Modbus message format.

  • Supports five independent server connections for Service Port 502
  • Supports five independent server connections for Service Port 2000
  • Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination
  • Modbus data types overlap in the gateway's memory database, so the same data can be read or written as bit-level or register-level data, whichever is most convenient.

 

Modbus Client (Master)

  • Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats
  • Offers one client connection with up to 100 commands to talk to multiple severs

 

Status Data

Error codes, counters, and port status available

 

CC-Link

CC-Link (Control & Communication Link) is an open-standard communication protocol that enables easy connection to Mitsubishi and other Master controllers.

  • CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide.
  • The ProLinx CCLINK interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer.
  • The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector.

 

Functional Specifications

Modbus TCP/IP 

Modbus Commands Supported (Server and Client)

1  : Read Coils

2  : Read Input Status

3  : Read Holding Registers

4  : Read Input Registers

5  : Force (Write) Single Coil

6  : Preset (Write) Single Holding Register

15 : Force (Write) Multiple Coils

16 : Preset (Write) Multiple Holding Registers

Configurable Parameters:

Server

ProLinx IP Address

Modbus  data type starting address offsets

Configurable parameters: Client

Min Command Delay

Response Timeout

Retry Count

Command Error Pointer

Command List

Up to 100 fully-configurable Client commands

Status Data

Error codes reported individually for each command

Polling of command list

Each command can be individually enabled or

disabled; write-only-on-data-change is available

 

CC-Link

CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing its I/O data transfer capacity.

Maximum Number of Occupied Stations

4 stations, consecutive addresses

Maximum Number of Devices per network

26-64 Devices depending on Local and Slave Stations configured

Device Types Supported

Intelligent Device and Local Station

CC-Link Version supported

CC-Link Version 1.10 cyclic data transmission

Message handling

Cyclic Messages and Transient Messages

Cyclic Data Capacity

24 input data words and 24 output data words.
Up to 4 slave stations supporting 4 words/32 bits per slave

Additional I/O Data Transfer Capacity

Transient Messaging extends the data transfer capacity to more than 8,000 additional words

Transient Message Commands

System Information, Memory Access Information, RUN, STOP, Line Test. Memory Read and Memory Write commands

Communication speed

10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps

Transmission path format

Bus format (EIA RS485 conformance)

Transmission format

HDLC conformance

Error control system

CRC (X16+X12+X5+1)

Hardware

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, and Ground terminals
2.5 mm screwdriver blade-sized terminals

Current Load

500 mA max@ 32 VDC max 

Operating Temperature

-20 to 50°C (-4 to 122°F) 

Storage Temperature

-40 to 85°C (-40 to 185°F) 

Relative Humidity

5% to 95% (non-condensing)

Dimensions

Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

General LED Indicators

Power and General Status
Application Status Serial Port Activity LED
Serial Activity and Error LED Status

CC-Link LED Indicators

Run (Network Status)
L Run (Data Link Execution)
L Err (Data Link Comm Error)
SD (Sending Data LED)
RD (Receiving Data LED)
ERR (Switch Setting Error)

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port

RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators

Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

CC-Link Interface

Pin

Description

DA

Data Communication line A

DB

Data Communication line B

DG

Digital Ground

SLD

Shield

FG

Frame Ground

 

Shipped with Each Unit

Mini-DIN to DB-9M serial cable
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
CC-Link to Terminal Block connector